Water safety

Legionella risk assessment, done properly and recorded.

If you are an employer or someone in control of premises, you have to assess and manage the risk of exposure to legionella. That means a risk assessment, a written scheme of control, and records of the checks being done. This page gives you the checklist, the PDF and a way to run the whole thing on a phone.

What the assessment has to cover

Legionella bacteria multiply in water systems that sit between 20°C and 45°C, particularly where water stagnates or where there is a source of nutrients such as rust, sludge and scale. Breathing in aerosol from a contaminated outlet can cause Legionnaires' disease. The assessment identifies where that could happen in your building, and the scheme of control sets out how you keep the risk down.

  • A named responsible person and a current risk assessment for every system.
  • Cold water stored and distributed below 20°C, with tanks covered and clean.
  • Hot water stored at 60°C or above and reaching 50°C or above within a minute.
  • Sentinel outlets, showers and little-used points flushed and tested to a schedule.
  • Cooling towers, humidifiers, spa pools and other aerosol sources included.
  • Records of every temperature, flush and clean, time-stamped and retained.

In England and Wales the duties sit in the Health and Safety at Work etc. Act 1974 and the Control of Substances Hazardous to Health Regulations, supported by the HSE's approved code of practice L8 and its technical guidance HSG274. The requirement is not to hold a document. It is to manage the risk, and to be able to show that you did.

Legionella risk assessment

Legionella assessment

6 of 18 answered · monthly

In progress

Question 6 · Hot water

Is the calorifier flow temperature at or above 60°C?

61.4 °C
✓ Yes

Tap, type, done. Under 10 seconds a question.

Question 7 · Sentinel outlet

Does the furthest sentinel tap reach 50°C within one minute?

Yes
✕ No
Reached 47°C in 60s

Photo added → action raised with owner

Submit assessment

ON THE PLATFORM

The assessor walks the building with the assessment open on a phone. A temperature is typed in and the question is answered in seconds. Anything out of range raises an action with an owner and a due date before the assessor has left the plant room.

No app install required on the web, offline completion on the mobile app, and a full history of every assessment so the monthly checks show as a routine rather than a scramble.

Download the assessment.

6 sections and 31 checks, following the structure of the HSE's L8 guidance. Print it, work through it, and keep the completed copy with your water treatment records.

Run it in Focus Point

How often

Cold water tank and temperature checks
Monthly, or to your written scheme
Sentinel outlet temperatures
Monthly
Shower and little-used outlet flushing
Weekly
Risk assessment review
At least every 2 years, or when the system changes
Full water system audit
Annually
01

Management and records

  • A named responsible person is accountable for water safety.
  • A current legionella risk assessment exists for every building and system.
  • A written scheme of control sets out what is checked and how often.
  • Water temperature and flushing records are complete and time-stamped.
  • The water system schematic and asset register are up to date.
  • Contractor competence and test certificates are held on file.
02

Cold water systems

  • Cold water is stored and distributed below 20°C.
  • Cold water tanks are covered, insulated, vermin proof and free of debris.
  • Tanks are inspected and cleaned on a recorded schedule.
  • No redundant pipework or dead legs remain in the system.
  • Cold water outlets are flushed where use is intermittent.
03

Hot water systems and temperatures

  • Water is stored at 60°C or above and distributed so it reaches 50°C or above within one minute.
  • Calorifier flow and return temperatures are recorded.
  • Thermostatic mixing valves are fitted where required and are serviced.
  • Sentinel taps, including the nearest and furthest outlet, are tested monthly.
  • Shower heads and hoses are cleaned and descaled quarterly, and the clean is recorded.
  • Any outlet falling outside range is escalated and re-tested.
04

Outlets and little-used points

  • Every outlet is used or flushed weekly and the flush is recorded.
  • Little-used rooms, including guest and respite rooms, are identified and flushed.
  • Fire hose reels, vehicle wash points and outside taps are included in the scheme.
  • Outlet aerators and strainers are clean and free of scale.
  • Infrequently used outlets are listed in the risk assessment.
05

Other risk systems

  • Cooling towers and evaporative condensers are registered with the local authority.
  • Humidifiers, air conditioning and spa pools are included in the assessment.
  • Decorative fountains and water features are cleaned and treated to a schedule.
  • Eyewash stations and emergency showers are flushed weekly.
  • Any system with a potential to produce aerosol is risk assessed.
06

Training and review

  • Staff responsible for water checks are trained and their competence is recorded.
  • The risk assessment is reviewed at least every two years or when the system changes.
  • Positive results or suspected cases trigger a documented response.
  • Audit findings are reviewed by management with actions owned and closed.

Water checks on a schedule, with the record kept.

Join the waiting list and we'll load the legionella assessment before launch on 15 December, with a 30-day free trial and no card required.